Deprecated: Required parameter $width follows optional parameter $attachment_id in /customers/f/0/0/geointec.com/httpd.www/wp-content/plugins/goodlayers-core/framework/function/utility.php on line 865 Deprecated: Required parameter $height follows optional parameter $attachment_id in /customers/f/0/0/geointec.com/httpd.www/wp-content/plugins/goodlayers-core/framework/function/utility.php on line 865 Deprecated: Required parameter $url follows optional parameter $social_list in /customers/f/0/0/geointec.com/httpd.www/wp-content/plugins/goodlayers-core/include/pb/pb-element-social-share.php on line 343 Warning: Cannot modify header information - headers already sent by (output started at /customers/f/0/0/geointec.com/httpd.www/wp-content/plugins/goodlayers-core/framework/function/utility.php:865) in /customers/f/0/0/geointec.com/httpd.www/wp-includes/rest-api/class-wp-rest-server.php on line 1758 Warning: Cannot modify header information - headers already sent by (output started at /customers/f/0/0/geointec.com/httpd.www/wp-content/plugins/goodlayers-core/framework/function/utility.php:865) in /customers/f/0/0/geointec.com/httpd.www/wp-includes/rest-api/class-wp-rest-server.php on line 1758 Warning: Cannot modify header information - headers already sent by (output started at /customers/f/0/0/geointec.com/httpd.www/wp-content/plugins/goodlayers-core/framework/function/utility.php:865) in /customers/f/0/0/geointec.com/httpd.www/wp-includes/rest-api/class-wp-rest-server.php on line 1758 Warning: Cannot modify header information - headers already sent by (output started at /customers/f/0/0/geointec.com/httpd.www/wp-content/plugins/goodlayers-core/framework/function/utility.php:865) in /customers/f/0/0/geointec.com/httpd.www/wp-includes/rest-api/class-wp-rest-server.php on line 1758 Warning: Cannot modify header information - headers already sent by (output started at /customers/f/0/0/geointec.com/httpd.www/wp-content/plugins/goodlayers-core/framework/function/utility.php:865) in /customers/f/0/0/geointec.com/httpd.www/wp-includes/rest-api/class-wp-rest-server.php on line 1758 Warning: Cannot modify header information - headers already sent by (output started at /customers/f/0/0/geointec.com/httpd.www/wp-content/plugins/goodlayers-core/framework/function/utility.php:865) in /customers/f/0/0/geointec.com/httpd.www/wp-includes/rest-api/class-wp-rest-server.php on line 1758 Warning: Cannot modify header information - headers already sent by (output started at /customers/f/0/0/geointec.com/httpd.www/wp-content/plugins/goodlayers-core/framework/function/utility.php:865) in /customers/f/0/0/geointec.com/httpd.www/wp-includes/rest-api/class-wp-rest-server.php on line 1758 Warning: Cannot modify header information - headers already sent by (output started at /customers/f/0/0/geointec.com/httpd.www/wp-content/plugins/goodlayers-core/framework/function/utility.php:865) in /customers/f/0/0/geointec.com/httpd.www/wp-includes/rest-api/class-wp-rest-server.php on line 1758 {"id":9554,"date":"2019-10-17T16:08:08","date_gmt":"2019-10-17T14:08:08","guid":{"rendered":"http:\/\/www.geointec.com\/?p=9554"},"modified":"2020-06-10T09:01:19","modified_gmt":"2020-06-10T07:01:19","slug":"campana-geotecnica-y-de-pull-out-test-en-seychelles","status":"publish","type":"post","link":"https:\/\/www.geointec.com\/campana-geotecnica-y-de-pull-out-test-en-seychelles\/","title":{"rendered":"CAMPA\u00d1A GEOT\u00c9CNICA Y DE PULL OUT TEST EN SEYCHELLES"},"content":{"rendered":"

Geointec<\/span><\/a> realiz\u00f3 una campa\u00f1a geot\u00e9cnica<\/a> y de Pull Out Test para la planta fotovoltaica de 5MW que se desarrollar\u00e1 en una isla artificial en Seychelles.<\/span><\/p>\n


\n

Con el objetivo de determinar las propiedades del suelo para el dise\u00f1o de la estructura que soportar\u00e1 los m\u00f3dulos solares de un proyecto fotovoltaico de 5MW, Geointec<\/a> desplaz\u00f3 hasta la Isla de Romanville a un equipo de dos ingenieros ge\u00f3logos para la realizaci\u00f3n de los Ensayos Geot\u00e9cnicos y de Pull Out Test.<\/span><\/p>\n

Los trabajos se llevaron a cabo en una isla artificial con una superficie aproximada de 18 hect\u00e1reas, ubicada a escasos metros de la costa de la isla de Mah\u00e9, en Seychelles.<\/span><\/p>\n

Una de las peculiaridades del proyecto, es que la planta solar comparte el espacio territorial con un parque e\u00f3lico de cinco turbinas, que opera actualmente en la isla, con capacidad de nominal por turbina de 750 kW (total 3,750 MWnom), conectada a la isla de Mah\u00e9 por canalizaci\u00f3n submarina.<\/span><\/p>\n

El estudio geot\u00e9cnico estuvo compuesto por ensayos a penetraci\u00f3n de energ\u00eda variable, resistividad t\u00e9rmica, corte directo in-situ, ensayos el\u00e9ctricos verticales. Tambi\u00e9n, se tomaron muestras de suelo para la determinaci\u00f3n de la corrosividad del terreno.<\/span><\/p>\n

Adem\u00e1s, el equipo de Geointec<\/a> realiz\u00f3 una campa\u00f1a de Hinca y Carga o de \u201cPull Out Test\u201d, que estuvo compuesta por 15 ensayos de hinca de carga horizontal y 15 ensayos de carga vertical, en los que se utilizaron perfiles de secci\u00f3n C120, que fueron transportados por v\u00eda mar\u00edtima, al igual que la maquinaria empleada durante la realizaci\u00f3n de las pruebas.<\/span><\/p>\n

Se prev\u00e9 que este proyecto<\/a> producir\u00e1 alrededor de 7 millones de kWh de energ\u00eda por a\u00f1o, lo que supondr\u00e1 aproximadamente el 1,8% del consumo total de energ\u00eda de Sheychelles<\/a>.<\/span><\/p>\n\n\n